Certifications and Calibration

Inspections, calibrations and comprehensive documentation to ensure the accuracy, repeatability, and compliance of your ultrasonic testing, both in the lab and on-site.

  • Calibration of UT/PAUT instruments, probes and measurement chains

  • Periodic inspections, MSA/GR&R, and control plans

  • Certified reference blocks and standards, traceability

  • Reports and certificates ready for quality audits

Certifications

Thanks to our team of highly specialized technicians, we are able to issue:

  • Declarations of conformity for sample blocks
  • V1 sample block certificates in accordance with UNI EN ISO 2400:2012
  • V2 sample block certificates in accordance with UNI EN ISO 7963:2010
  • Certificates for sample blocks in accordance with ASTM E127-20
  • Certificates for ultrasonic probes in accordance with UNI EN ISO 22232-2:2021
  • Calibration certificates for flaw detector instruments
  • ASTM E 317-21 Ultrasonic Testing (UT)
  • ASME V Ultrasonic Testing (UT)
  • UNI EN ISO 22232-1:2021 Ultrasonic Testing (UT)
  • ASTM E 2491-13R18 Phased Array Flaw Detectors
  • ASTM E 317-21 Ultrasonic Thickness Gauges
  • ASTM E 797/E797M-21 Ultrasonic Velocity Gauges
Most common non-conformities
  • Channel drift, declining SNR, unstable gates

  • Worn probes or connectors/cables that affect sensitivity

  • Expiration of certificates, lack of historical traceability

  • Software/firmware updates with misaligned parameters

  • Encoders/synchronization issues on automated lines

Scope and calibration parameters
  • Instrumentation: Conventional UT and PAUT, multichannel, dedicated HMIs
  • Parameters: A/B/C-scan, gate, DAC/TCG, filters, PRF, focal lengths/angles
  • Probes: contact/immersion, dual-element, Phased Array
  • Automated lines: encoders, triggers, synchronization, I/O and safety
  • Data quality: SNR, repeatability, performance trends and control limits
What we offer
Calibration of UT/PAUT instruments

Channel alignment, PRF/focal length settings (where applicable), gate calibration, DAC/TCG curves, A/B/C-scan functional checks.

Probes & Accessories

Check sensitivity, frequency response, array uniformity and cable/connector integrity; recondition or replace as necessary.

Periodic inspections and MSA

Interim inspection plans, GR&R, control charts and operational checklists to reduce drift between calibrations.

References and sample blocks

Selection and supply of certified blocks and standards (V1/V2, side holes, notches, etc.) with traceability management.

Quality documentation

Test reports, calibration certificates, PDF/CSV reports, results archive; optional digital signature and photo attachments.

On-site and lab

On-site work on production lines and test benches, or laboratory work with tracked RMA and defined timelines.

How we work

1.

Requirement analysis

Tools/probes, tolerances, standards and deadlines

2.

Calibration plan

References, methods, test sequence, safety

3.

Implementation and verification

Functional checks, channel/probe calibration, encoder/synchronization checks (optional MSA/GR&R)

4.

Report and certificates

Document issuance, result archiving and traceability

5.

Regular program

Recall deadlines, interim reviews, audit readiness

1.

Requirement analysis

Tools/probes, tolerances, standards and deadlines

2.

Calibration plan

References, methods, test sequence, safety

3.

Implementation and verification

Functional checks, channel/probe calibration, encoder/synchronization checks (optional MSA/GR&R)

4.

Report and certificates

Document issuance, result archiving and traceability

5.

Regular program

Recall deadlines, interim reviews, audit readiness

Discover our other services

Custom
solutions

Repairs and
technical support

Training and
education

Contact us

and request a free quote!

    Help us understand your operating environment better:

    Frequently Asked Questions

    It depends on the criticality, usage, and contractual requirements. Generally: periodic calibration + interim checks using control charts.
    Yes. We perform on-site calibrations with minimal downtime and check encoders and synchronization.
    Yes. We issue reports and certificates that include references, results, and traceability; digital signatures are available.
    Yes. Let’s set up a regular schedule with reminders for deadlines and mid-term reviews.
    Of course: we measure repeatability and reproducibility and provide metrics and operational recommendations.